Product Identification

Product ID:SOLUTION S0191 EX-1
MSDS Date:05/15/1989
FSC:6810
NIIN:00N024014
MSDS Number: BMFKD

Responsible Party
NALCO CHEMICAL CO
ONE NALCO CENTER
NAPERVILLE, IL 60566-1024
US

Emergency Phone: 708-920-1510

Info Phone: 708-961-9500

Preparer: JOHN J. KASPER

Cage: 89524

Contractor
ONDEO NALCO COMPANY
NAPERVILLE, IL 60563-1198 US

Telephone: (630) 305-1000

Cage: 89524

Ingredients

HYDROCHLORIC ACID; (HYDROGEN CHLORIDE)

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: 20-40%

OSHA PEL 5 PPM, C

ACGIH TLV: 5 PPM, C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


WHICH HAS PH CNTRL SYS IN OPER.EMPTY PROD

RTECS: 9999999ZZ


COLLECTION CONTAINER.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) 900 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: CORROSIVE TO EYES WITH POSSIBLE
PERMANENT DAMAGE DEPENDING ON LENGTH OF EXPOSURE AND ON FIRST AID
ACTION GIVEN. SKIN: CORROSIVE TO SKIN, POSSIBLY RESULTING IN THIRD
DEGREE BURNS DEPENDING ON LENG TH OF EXPOSURE AND ON FIRST AID
ACTION GIVEN. INGESTION: CAN BE HARMFUL. INHALATION: CAN BE
CORROSIVE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: TO MUCOUS MEMBRANES AND LUNGS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IMMED FLUSH FOR AT LEAST 15 MIN WHILE HOLDING EYELIDS
OPEN. CALL PHYS AT ONCE. SKIN: IMMED FLUSH W/H*2O FOR AT LEAST 15
MIN. FOR LRG SPLASH, FLOOD BODY UNDER SHOWER. CALL PHYS AT ONCE.
INGEST: D O NOT INDUCE VOMIT. GIVE H*2O. CALL PHYS. INHAL: REMOVE
TO FRESH AIR. TREAT SYMP. CALL PHYS. CAUTION: IF UNCON, HAVING
TROUBLE BRTHG/IN CONVULSIONS, DO NOT INDUCE VOMIT/GIVE H*2O. NOTE
TO (SUPP DATA)

Fire Fighting

Flash Point:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:ACID REACTS WITH MOST METALS TO RELEASE
HYDROGEN GAS, WHICH CAN FORM EXPLOSIVE MIXTURES WITH AIR.

Accidental Release

Spill Release Procedures:SMALL LIQ SPILLS: COVER SPILL W/SODIUM
BICARBONATE/SODA ASH/LIME MIX. MIX & ADD H*2O TO FORM SLURRY. FLUSH
DOWN DRAIN WITH LARGE AMOUNTS OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:WARNING: CAUSES BURNS TO SKIN AND
EYES. DO NOT GET IN EYES, ON SKIN, OR ON CLOTHING. AVOID BREATHING
VAPORS. DO NOT TAKE INTERNALLY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:RESPIRATORY PROTECTION IS NOT NORMALLY NEEDED.
USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN .
Ventilation:GEN VENT IS RECOM. ADDITIONALLY, LOCAL EXHAUST VENTILATION
IS RECOMMENDED WHERE VAPORS, MISTS OR AEROSOLS MAY BE RELSD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WRKRS GOG & FULL LGTH FSHLD .
Other Protective Equipment:THE AVAILABILITY OF AN EYE WASH FOUNTAIN AND
SAFETY SHOWER IS RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MATLS TO AVOID: HYDROXIDE (LIME), CYANIDES, SULFIDES, HYPOCHLORITES,
CHLORITES) WHICH CAN GENERATE HEAT W/SPLATTERING/BOILING & RELS OF
TOX FUMES. FIRST AID PROC: PHYS: PROBABLE MUCOSAL DMG MAY CONTRA
INDICATE USE OF GASTRIC LAVAGE. MEASURES AGAINST CIRCULATORY SHOCK,
RESP DEPRESSION & CONVULSIONS MAY BE NEEDED.

Chemical Properties

HCC:C1
pH:<1
Solubility in Water:COMPLETELY
Appearance and Odor:COLORLESS LIQUID, SHARP ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
ALKALINE MATLS (EG.AMMONIA & ITS SOLNS, CARBONATES, SODIUM HYDROXIDE
(CAUSTIC),POTASSIUM HYDROXIDE, CALCIUM (SUPP DATA)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HCL

Disposal

Waste Disposal Methods:IF PROD BECOMES WASTE, IT MEETS CRITERIA OF HAZ
WASTE AS DEFINED UNDER RCRA 40 CFR 261. HAZ WASTE D002. ACID SOLNS
SHD BE NEUT BEFORE BEING DISCHARGED TO SANITARY SEWER.
ALTERNATIVELY, AN ACID SOLN MA Y BE DISP INTO WASTE TREATMENT PLANT
(INGRED 2)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,